7-76 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

P-0-0442, Actual value torque limit positive (stationary)<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- S-0-0086<br />

Display parameter for the effective positive torque limit value. The value<br />

displayed is the lowest value of<br />

• S-0-0092, Bipolar torque/force limit value<br />

• P-0-0109, Torque/force peak limit<br />

• S-0-0082, Torque/force limit value positive<br />

• work load-dependent limits by motor and controller<br />

• motor depending limits.<br />

P-0-0443, Actual value torque limit negative (stationary)<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- S-0-0086<br />

Display parameter for the effective negative torque limit value. The value<br />

displayed is the lowest value of<br />

• S-0-0092, Bipolar torque/force limit value<br />

• P-0-0109, Torque/force peak limit<br />

• S-0-0083, Torque/force limit value negative<br />

• work load-dependent limits by motor and controller<br />

• motordepending limits.<br />

See also Functional Description "Torque/Force Limitation"<br />

P-0-0444, Actual value peak torque limit<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- S-0-0086<br />

Display parameter for the maximum drive torque or the maximum drive<br />

force. The value is the limit value for positive and negative torque/force<br />

command values.<br />

The value displayed is the lower value of<br />

• P-0-0109, Torque/force peak limit<br />

• S-0-0092, Bipolar torque/force limit value<br />

• work load-dependent limits by motor and controller<br />

• motor-dependent limits.<br />

The unit for the values of this parameter depends on the scaling that has<br />

been set (S-0-0086, Torque/force data scaling type).<br />

See also Functional Description "Torque/Force Limitation"<br />

DOK-INDRV*-FU*********-IB01-EN-P