<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-49<br />

Function<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

S-0-0349, Jerk limit bipolar<br />

Input min/max: Default value: Unit:<br />

MPB: 0 S-0-0160<br />

The bipolar jerk limit value, in the operating modes listed below, describes<br />

the maximum allowed acceleration change per time (= jerk),<br />

symmetrically in both directions (acceleration and deceleration).<br />

The limit value takes effect in the following operating modes:<br />

• Position control<br />

• drive-internal interpolation<br />

• drive-controlled positioning<br />

Note: The bipolar jerk limit value limits the change in acceleration<br />

per time for "<strong>Drive</strong> Halt", the error reaction quick stop (velocity<br />

command value reset with filter and ramp) and the commands<br />

that are generating their own position command values. The<br />

value "0" switches the jerk filter off!<br />

See also Functional Description "Establishing the Position Data<br />

Reference (<strong>Drive</strong> Controlled Homing)"<br />

See also Functional Description "Spindle Positioning"<br />

See also Functional Description "<strong>Drive</strong> Functions - <strong>Drive</strong> Halt"<br />

S-0-0375, List of diagnostic numbers<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

The drive enters every change of parameter S-0-0390, Diagnostic<br />

message number in this list. The list is organized as a ring buffer; it can<br />

contain up to 50 diagnostic message numbers. When the list is read, the<br />

last diagnostic message number displayed is displayed in the 1 st element<br />

of the parameter.<br />

See also Functional Description "Diagnostic System"<br />

S-0-0380, DC bus voltage<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- V<br />

This parameter is used to display the DC bus voltage currently measured.<br />

S-0-0382, DC bus power<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- Watt<br />

This parameter displays the DC bus power currently demanded by the motor.