7-6 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Communication Phase 3<br />

Transition Check<br />

The procedure comprises several steps and is controlled by the master by<br />

presetting communication phases –1 to 4 and starting/completing the<br />

following commands:<br />

• S-0-0127, C0100 Communication phase 3 transition check<br />

• S-0-0128, C0200 Communication phase 4 transition check<br />

.<br />

When the drive has reached communication phase 4 without error, the<br />

display reads "bb".<br />

The corresponding diagnostic message is:<br />

• A0013 Ready for power on<br />

Transition Check Commands<br />

To switch from communication phase 2 to 3 and from 3 to 4 it is<br />

necessary to activate transition check commands in the drive:<br />

• S-0-0127, C0100 Communication phase 3 transition check<br />

• S-0-0128, C0200 Communication phase 4 transition check<br />

Note: In order to get back from the operating mode to the<br />

parameterization mode, there is the command P-0-4023,<br />

C0400 Communication phase 2 transition.<br />

By executing the command S-0-0127, C0100 Communication phase 3<br />

transition check a number of checks and parameter conversions are<br />

carried out that can possibly cause the listed command errors:<br />

• Checking whether functional package selection was changed<br />

• C0199 Functional package selection changed. Restart<br />

→ drive has to be rebooted before it is possible to switch to<br />

phase 3<br />

• Checking validity of parameters required for switching to phase 3<br />

If one of these parameters has never been written or the backup was<br />

carried out incorrectly, the error message "C0101" is generated. The<br />

IDNs of the faulty parameters are listed in parameter S-0-0021, IDN<br />

list of invalid operating data for communication phase 2. These<br />

parameters have to be set valid by writing correct values to them.<br />

• C0101 Invalid parameters (-> S-0-0021)<br />

• Checking device configuration<br />

• C0132 Invalid settings for controller cycle times<br />

• C0138 Invalid amplifier data (->S-0-0021)<br />

• Checking telegram configuration, especially in the case of configured<br />

telegrams<br />

In this case a check is run to find out whether the parameters selected<br />

for the configurable data block in the cyclic command value channel<br />

(MDT) or actual value channel (AT) may be configured and whether<br />

the allowed length of the configurable data blocks is complied with.<br />

• C0104 Config. IDN for MDT not configurable<br />

• C0105 Maximum length for MDT exceeded<br />

• C0106 Config. IDNs for AT not configurable<br />

• C0107 Maximum length for AT exceeded<br />

• If necessary, checking timing parameters for SERCOS communication<br />

in phases 3 and 4 for validity and compliance with requirements<br />

• C0108 Time slot parameter > Sercos cycle time<br />

• C0109 Position of data record in MDT (S-0-0009) even<br />

DOK-INDRV*-FU*********-IB01-EN-P