<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-127<br />

Internally Calculated Parameter<br />

Values<br />

Annotations<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

third-party motors (asynchronous)<br />

motor data<br />

on<br />

type plate<br />

1. manual input of data from<br />

type plate in parameter<br />

P-0-4032<br />

2. automatic calculation of<br />

motor parameters via<br />

command C3200<br />

motor parameters<br />

(S-0-0109, P-0-4016, P-0-4039, P-0-4048, ...)<br />

automatic calculation of motor control<br />

parameters via already activated<br />

command C3200<br />

motor control parameters<br />

(S-0-0106, S-0-0107, P-0-0532, ...)<br />

DF000162v01_en.fh7<br />

Fig. 7-59: Functions of C3200 Command Calculate motor data<br />

Note: The type plate does not contain the complete information<br />

required for safe operation of the third-party motor!<br />

All required data are part of the form of manufacturer-side<br />

motor data which has to be available in completed form. The<br />

additional data, however, are not required for executing the<br />

command C3200.<br />

By activating the command C3200 (P-0-4033) the following parameter<br />

values are calculated from the data of the asynchronous motor entered in<br />

list parameter P-0-4032:<br />

• motor parameters<br />

• motor parameters, general (for synchronous and asynchronous<br />

motors)<br />

• specific motor parameters for asynchronous motors<br />

• motor control parameters<br />

• motor control parameters for field-oriented current control (FOC) of<br />

synchronous and asynchronous motors<br />

• motor control parameters for field-oriented current control (FOC) of<br />

asynchronous motors<br />

• motor control parameters for voltage-controlled operation (U/f) of<br />

asynchronous motors without encoder<br />

As regards the operating principle of the command C3200, observe the<br />

following points: