8-12 Diagnostic and Service Functions <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Display at comfort control panel<br />

S-0-0095, Diagnostic message text<br />

C0501 C0501 Error clearing only in parameter<br />

mode<br />

C06 C0600 <strong>Drive</strong>-controlled homing procedure<br />

command<br />

C0601 C0601 Homing only possible with drive<br />

enable<br />

C0602 C0602 Distance home switch - reference<br />

mark erroneous<br />

C0604 C0604 Homing of absolute encoder not<br />

possible<br />

See documentation "Troubleshooting Guide"<br />

1 2<br />

1<br />

Contact our sales and service facility<br />

1 3 2<br />

1 3 2<br />

1 3 2<br />

Contact machine manufacturer / installation<br />

programmer<br />

Check motor incl. holding brake, battery, encoder and<br />

cooling system<br />

Switch supply unit off and on again<br />

Switch drive controller off and on again<br />

Check encoder function and mounting (motor encoder<br />

and external encoder))<br />

C0606 C0606 Reference mark not detected 4 5 2 3 2 1<br />

C0607 C0607 Home switch input not assigned 1 3 2<br />

C0702 C0702 Default parameters not available 1 2<br />

C0703 C0703 Default parameters invalid 3 2 1<br />

C0704 C0704 Parameters not copyable 1<br />

C0706 C0706 Error when reading the controller<br />

parameters<br />

C0722 C0722 Parameter default value incorrect<br />

(-> S-0-0423)<br />

C0723 C0723 Safety command for load defaults<br />

procedure incorrect<br />

C0724 C0724 Timeout of safety command for<br />

load defaults procedure<br />

C0751 C0751 Parameter default value incorrect<br />

(-> S-0-0423)<br />

1 2<br />

4 3 1 2<br />

1 3 2<br />

1 3 2<br />

1 2<br />

C0752 C0752 Locked with password 1 3 2<br />

C0799 C0799 An invalid index was set 1 2<br />

C09 C0900 Position spindle command 1<br />

C0902 C0902 Spindle positioning requires drive<br />

enable<br />

1 3 2<br />

C0903 C0903 Error during initialization 1 3 2<br />

C0906 C0906 Error during search for zero pulse 2 4 3 1<br />

C12 C1200 Commutation offset setting<br />

command<br />

C1204 C1204 Error in offset calculation 1<br />

C1208 C1208 No adjustment with asynchronous<br />

motor<br />

1<br />

1 2<br />

C1209 C1209 Proceed to phase 4 1 2<br />

C1214 C1214 Command only possible with<br />

linear synchronous motor<br />

1 2<br />

C1215 C1215 Command only possible in 'bb' 1 2<br />

Check encoder cabling<br />

Check motor cabling<br />

Check wiring of inputs and outputs and their 24V<br />

power supply<br />

Check connection of master communication<br />

Check control circuit for mains connection<br />

Check mechanical system (stiffness, loose<br />

connection,...)<br />

DOK-INDRV*-FU*********-IB01-EN-P