<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-59<br />

Function<br />

Function<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

With this parameter it is possible to determine and activate an individual<br />

undervoltage threshold, differing from the standard value, for the DC bus<br />

voltage.<br />

P-0-0115, Device control: status word<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

By means of this parameter it is possible to read the drive (� status<br />

device control) independent of the master communication that is used.<br />

See also Functional Description "Master Communication"<br />

See also Functional Description "<strong>Drive</strong> Functions - <strong>Drive</strong> Halt"<br />

P-0-0116, Device control: control word<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter indicates whether the master communication has<br />

activated the drive.<br />

P-0-0117, Activation of NC reaction on error<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 0 --<br />

This parameter allows activating an error reaction controlled by the control<br />

unit. When error reaction controlled by the control unit is active, the<br />

control unit (external control/NC or local MLD) still can input command<br />

values for the drive for 30 s. This allows realizing an error reaction<br />

coordinated by the control unit in the case of error.<br />

Note: When the 30 seconds are over, the error reaction set in<br />

P-0-0119, Best possible deceleration is carried out.<br />

See also Functional Description "NC Reaction on Error"<br />

P-0-0118, Power supply, configuration<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 3 --<br />

In parameter P-0-0118 settings with regard to error messages and error<br />

reactions are made for drives that are interconnected via the DC bus and<br />

the module bus ("drive system"). In addition, the handling of DC bus<br />

undervoltage is determined.<br />

Note: The DC bus voltage (power bus) for the "drive system" in<br />

operation is not switched off in the case of non-fatal drive<br />

errors!<br />

See also Functional Description "Power Supply"