<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-91<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

• channel for velocity command value input (memory of fixed values or<br />

S-0-0036)<br />

• behavior of ramp generator (run-up stop)<br />

• command value generator (motor potentiometer)<br />

Note: The control word can be cyclically written, the assignment of<br />

individual bits from signal control word or digital inputs is<br />

possible, too. In contrast to P-0-1214, parameter P-0-1200 is<br />

stored in the drive in volatile form!<br />

See also Functional Description "Operating Mode: Velocity Control/Motor<br />

Potentiometer"<br />

P-0-1201, Ramp 1 pitch<br />

Input min/max: Default value: Unit:<br />

MPB: 0 S-0-0160<br />

The acceleration entered in P-0-1201, Ramp 1 pitch takes effect in the<br />

"velocity control" mode during acceleration.<br />

See also Functional Description "Operating Modes - Velocity Control"<br />

P-0-1202, Final speed ramp 1<br />

Input min/max: Default value: Unit:<br />

MPB: 0 S-0-0044<br />

The parameter P-0-1202, Final speed ramp 1 takes effect in the "velocity<br />

control" mode during acceleration and deceleration.<br />

When exceeding (acceleration) or falling below (deceleration) the velocity<br />

indicated in P-0-1202, Final speed ramp 1, the pitch of the drive-internal<br />

speed command value ramp changes as follows:<br />

• from the value indicated in P-0-1201, Ramp 1 pitch to the value<br />

indicated in P-0-1203, Ramp 2 pitch (acceleration)<br />

• or from the value indicated in P-0-1211, Deceleration ramp 1 to the<br />

value indicated in P-0-1213, Deceleration ramp 2 (deceleration).<br />

See also Functional Description "Velocity Command Value Reset with<br />

Filter and Ramp (Quick Stop)"<br />

P-0-1203, Ramp 2 pitch<br />

Input min/max: Default value: Unit:<br />

MPB: 0 S-0-0160<br />

The acceleration entered in P-0-1203, Ramp 2 pitch takes effect in the<br />

"velocity control" mode during acceleration.<br />

With the acceleration entered in this parameter, the acceleration takes<br />

place from the last effective command value to the new preset command<br />

value as soon as the velocity at the ramp output is greater than the value<br />

entered in P-0-1202, Final speed ramp 1.<br />

Influence of P-0-1209