7-86 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

Function<br />

Function<br />

P-0-0815, Nominal mains voltage crest value<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- V<br />

This parameter for HCS converters displays the mains voltage crest value<br />

that was measured when the mains voltage was switched in the first time.<br />

From this value the standard value for the undervoltage threshold<br />

(P-0-0114), the standard minimum value of the mains voltage crest value<br />

(P-0-0810) and the standard switch-on threshold of a braking resistor<br />

(P-0-0858) are derived.<br />

P-0-0819, Energy counter<br />

Input min/max: Default value: Unit:<br />

MPB:-20000000,00 / 20000000,00 0,00 kWh<br />

This parameter displays the energy which was supplied to the drive. The<br />

energy is determined by means of the operating time as the sum of the<br />

effective power.<br />

P-0-0833, Braking resistor threshold<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- V<br />

The braking resistor is only switched on via the firmware if this is required<br />

for braking. This means that it is switched on whenever the DC bus<br />

voltage is higher than the voltage threshold P-0-0833, Braking resistor<br />

threshold.<br />

P-0-0844, Braking resistor load<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- %<br />

This parameter indicates the thermal energy in percent, in relation to its<br />

maximum allowed energy content, currently stored in the braking resistor.<br />

P-0-0858, Data of external braking resistor<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

For HCS02/HCS03 converters the type data of an externally connected<br />

braking resistor are entered in this list parameter.<br />

Note: For HCS03 devices there is only an optional external braking<br />

resistor available!<br />

See also Functional Description "Power Supply"<br />