<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-5<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

• all factory-specific settings (can only be changed via master<br />

password)<br />

• P3: When changing from P2 → P3 only the parameters that can be<br />

changed in phase 2 (see above) are checked.<br />

In phase 3 the following parameters can be changed:<br />

• parameters for operating mode configuration<br />

• error reaction settings<br />

• motor configuration parameters, holding brake parameters<br />

• encoder configuration parameters<br />

• mechanical transmission elements (gear, feed constant)<br />

• scaling and polarity parameters, position data format, modulo value<br />

• configuration of analog and digital inputs/outputs<br />

• configuration of switch on / switch off sequence of drive enable<br />

(waiting times, ...)<br />

Note: According to SERCOS specification, the parameterization<br />

mode is divided into phases 2 and 3. In phase 3 the limit<br />

values for all scaling-dependent parameters are not yet<br />

known. When these parameters are written in phase 3, the<br />

extreme value check is only carried out during phase switch to<br />

phase 4.<br />

• P4: In phase 4, the so-called operating mode, only the cyclic data can<br />

be changed, the configuration parameters cannot. The switch to the<br />

operating mode always causes a new initialization of all functions<br />

available in the drive.<br />

The supported communication phases, as well as the handling of the<br />

switching between the communication phases (e.g. parameterization and<br />

operating mode) are depending on the master communication that is<br />

used. The control information preset for master communication is<br />

displayed in parameter P-0-4086, Master communication status.<br />

• SERCOS interface<br />

For SERCOS devices all 5 communication phases (as well as<br />

phase –1 → baud rate scan) are supported. According to SERCOS<br />

specification, switching takes place by setting the communication<br />

phase by the master.<br />

• Field bus interface<br />

For field bus devices only the communication phases 2 to 4 are<br />

supported!<br />

Switching takes place in the freely configurable operating mode<br />

(P-0-4084 = 0xFFFE) by presetting the desired mode via bit 1 in<br />

P-0-4077, Field bus: control word.<br />

Switching can also take place by executing the transition check<br />

commands (see below).<br />

• Parallel/analog interface<br />

For devices with analog or parallel interface only the communication<br />

phases 2 to 4 are supported!<br />

Switching always takes place when the transition check commands<br />

(see below) are executed.<br />

After the controller is switched on it does not automatically go to the<br />

operating mode, but has to be switched to this mode by the master.<br />

This switching of the drive controller to the operating mode is closely<br />

connected to establishing the readiness for operation.