02.02.2013 Views

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-27<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

Enter Motor Data:<br />

At the beginning of parameterization you must enter the motor data (see<br />

type plate of motor).<br />

Data field in which you can make inputs is highlighted in black.<br />

Fig. 7-19: Enter motor data (example)<br />

List<br />

element<br />

Characteristic<br />

value of motor Unit Definition<br />

0 rated current Aeff rms value of the electric current in<br />

the motor feed wire (motor phase) at<br />

rated load<br />

1 rated voltage Veff rms value of the phase-to-phase<br />

voltage between the motor terminal<br />

pins at rated load<br />

2 rated frequency Hz frequency of the feeding, sinusoidal<br />

electric voltage<br />

3 rated speed 1/min speed of motor output shaft at rated<br />

load<br />

4 power factor cos φ 1 power factor at rated load<br />

5 rated power kW mechanical power that can be<br />

continuously delivered at rated load<br />

Fig. 7-20: List elements P-0-4032<br />

• Data field in which you can make inputs is highlighted in black.<br />

• With key ▲ or ▼ you can select a specific data field.<br />

• With keys ◄, ►, Prog + , ⎺Mon enter desired value:<br />

◄, ►: move cursor to the left or to the right<br />

Prog + , ⎺Mon: change setting<br />

• With Enter key confirm entered value.<br />

Next data field is automatically activated.<br />

• When you have made all inputs:<br />

Press Esc key.