<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Diagnostic and Service Functions 8-25<br />

General Notes on How to Carry<br />

Out Firmware Replacement<br />

Firmware Release Update<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

You have to observe the following points when carrying out the firmware<br />

replacement:<br />

• Do not switch off the 24 V control voltage while replacing the firmware.<br />

• Firmware replacement always must be carried out completely, i.e.<br />

firmware on optional safety technology module must be replaced, too.<br />

• For firmware replacement we distinguish between release update and<br />

version upgrade.<br />

Note: When firmware is replaced in conjunction with the option<br />

starting lockout ("L1"), this does not require any specific<br />

measure, i.e. the additional measures described below only<br />

apply to the use of option "S1"!<br />

When firmware in a drive controller is replaced by firmware of a new<br />

release, this is called firmware release update (e.g. FWA-INDRV*-<br />

MPH-04V06-D5 replaced by FWA-INDRV*-MPH-04V08-D5).<br />

The described sequences of the firmware release update depend on the<br />

configuration of the control section and the hardware (MMC or PC) used<br />

for update. The basically recommended sequence of the firmware release<br />

update is illustrated in the scheme below: