8-34 Diagnostic and Service Functions <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Selection Criterion<br />

Firmware Upgrade with<br />

IndraWorks D<br />

Variant 3: Version Upgrade with IndraWorks D<br />

The following requirements should have been fulfilled in order that<br />

carrying out the firmware version upgrade with IndraWorks D makes<br />

sense:<br />

• Controller has been equipped with BASIC single-axis control section.<br />

• Current parameter setting of axis was saved.<br />

Carrying out the firmware version upgrade with IndraWorks D requires the<br />

following steps:<br />

1. Load firmware<br />

Call IndraWorks D.<br />

⇒<br />

Load project for corresponding axis or create new project. To do this,<br />

⇒<br />

address axis via a serial connection.<br />

Switch project "online".<br />

⇒<br />

Select/highlight controller and call "Firmware management" in context<br />

⇒<br />

menu.<br />

→A new window opens and firmware currently available in drive is<br />

displayed on its right side. On left side of window, firmware available<br />

in current firmware directory is displayed.<br />

Highlight new firmware (*.ibf file) on left side and start firmware<br />

⇒<br />

download via "Download" button.<br />

→ Firmware download runs automatically and all required firmware<br />

components are loaded to drive.<br />

After firmware download has been completed, close "Firmware<br />

⇒<br />

management" window.<br />

2. Put drive into ready-for-operation status<br />

⇒ Switch project "offline" and then "online" again.<br />

→ After project has been switched online, a message signals that<br />

IndraWorks D could not establish communication to drive via serial<br />

interface, as drive-internal settings for serial communication were<br />

reset.<br />

Reconfigure communication via button "Search for devices".<br />

⇒ As firmware in drive no longer complies with version stored in project,<br />

a corresponding message is displayed. To adjust firmware version in<br />

project, first select option "Repair" and then options "Delete existing<br />

drive from project" and "Add new drive to project".<br />

⇒ As number of parameters to be buffered has changed, "PL" appears<br />

on display (in case errors are present, clear them first). If you now<br />

press "Esc" key, all buffered parameters are set to their default<br />

values. During this time, message "C07 Load default parameters"<br />

appears on display.<br />

3. Load parameter values<br />

⇒ Load parameter file which was saved.<br />

4. Put machine into ready-for-operation status<br />

Put machine into ready-for-operation status again according to<br />

⇒<br />

machine manufacturer's instructions.<br />

Check functions of drive.<br />

⇒<br />

DOK-INDRV*-FU*********-IB01-EN-P