7-94 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

With the deceleration entered in this parameter, the deceleration takes<br />

place from the last effective velocity command value to the new velocity<br />

command value as soon as the velocity at the ramp output is smaller than<br />

the value in P-0-1202, Final speed ramp 1.<br />

See also Functional Description "Velocity Command Value Reset with<br />

Filter and Ramp (Quick Stop)"<br />

P-0-1213, Deceleration ramp 2<br />

Input min/max: Default value: Unit:<br />

MPB: 0 S-0-0160<br />

The deceleration entered in P-0-1213, Deceleration ramp 2 takes effect<br />

in the "velocity control" mode during the deceleration process.<br />

With the deceleration entered in this parameter, the deceleration takes<br />

place from the last effective velocity command value to the new velocity<br />

command value as long as the velocity at the ramp output is greater than<br />

the value in P-0-1202, Final speed ramp 1.<br />

See also Functional Description "Velocity Control Mode"<br />

P-0-1214, Control word 2 velocity control<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 0 --<br />

Via this parameter it is possible to influence, i.e. to control, the execution<br />

of a velocity control mode in the operating mode.<br />

Note: P-0-0088 can be configured in the cyclic command value<br />

telegram!<br />

See also Functional Description "Operating Modes - Velocity Control"<br />

P-0-1215, Motor potentiometer, acceleration<br />

Input min/max: Default value: Unit:<br />

MPB: 100000 S-0-0160<br />

In conjunction with the motor potentiometer available in the "velocity<br />

control" mode, this parameter is used for the following purposes:<br />

• For linear velocity change:<br />

Definition of the velocity change by which the ramp velocity changes<br />

when setting P-0-1214, bit8 ("ramp+")<br />

�∆P-0-1218 = activation time * [P-0-1215]<br />

• For square velocity change:<br />

Definition of the acceleration change by which the ramp velocity<br />

changes within 2 s when setting P-0-1214, bit8 ("ramp+")<br />

�∆acceleration = activation time * ( [P-0-1215] / 2 s)<br />

Note: With the input activated the velocity is increased in linear or<br />

square form (see P-0-1214, Motor potentiometer, control<br />

DOK-INDRV*-FU*********-IB01-EN-P