<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-65<br />

Function<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

MPB: --- / --- 0 --<br />

In this parameter the IDN of that parameter is entered to which a value<br />

corresponding to the voltage at the respective analog input is to be<br />

written. The scaling is made via P-0-0214, Analog input, assignment A,<br />

scaling per 10V full scale!<br />

Note: Only such IDNs can be entered in P-0-0213 that are contained<br />

in P-0-0212, Analog input, list of assignable parameters.<br />

See also Functional Description "Analog Interface"<br />

See also Functional Description "Analog Inputs"<br />

P-0-0214, Analog input, assignment A, scaling per 10V<br />

full scale<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 0 --<br />

By means of this parameter the analog input for assignment A (range of<br />

values per 10 V) is scaled.<br />

Unit, decimal places and data type are determined by the parameter<br />

assigned in P-0-0213, Analog input, assignment A, target parameter.<br />

See also Functional Description "Analog Interface"<br />

See also Functional Description "Analog Inputs"<br />

P-0-0215, Analog input, assignment A, signal value at 0V<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 0 --<br />

In this parameter the reference of the analog input for assignment A<br />

(value with a voltage of 0 V at the analog input) is defined. This allows<br />

compensating a possible offset of the voltage at the analog input for<br />

assignment A.<br />

Unit, decimal places and data type are determined by the parameter<br />

assigned in P-0-0213, Analog input, assignment A, target parameter.<br />

See also Functional Description "Analog Interface"<br />

See also Functional Description "Analog Inputs"<br />

P-0-0216, Analog input, assignment A, dead zone<br />

Input min/max: Default value: Unit:<br />

MPB: 0,000 / 10,000 0,000 V<br />

By means of this parameter it is possible to define, for the analog input<br />

voltage (assignment A), a range of values that is interpreted as voltage<br />

value 0 V ("dead zone") by the drive controller.<br />

See also Functional Description "Analog Interface"