<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Diagnostic and Service Functions 8-9<br />

Display at comfort control panel<br />

S-0-0095, Diagnostic message text<br />

C0114 C0114 T4 > TScyc (S-0-0002) - T4min<br />

(S-0-0005)<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

See documentation "Troubleshooting Guide"<br />

Contact our sales and service facility<br />

1 3 2<br />

C0115 C0115 T2 too small 1 3 2<br />

C0116 C0116 T3 (S-0-0008) within MDT (S-0-<br />

0089 + S-0-0010)<br />

1 3 2<br />

C0119 C0119 Max. travel range too large 1 3 2<br />

C0120 C0120 Error when reading encoder data<br />

=> motor encoder<br />

C0121 C0121 Incorrect parameterization of<br />

motor encoder (hardware)<br />

C0122 C0122 Incorr. parameteriz. of motor enc.<br />

(mechanical system)<br />

C0123 C0123 Modulo value for motor encoder<br />

cannot be displayed<br />

Contact machine manufacturer / installation<br />

programmer<br />

Check motor incl. holding brake, battery, encoder and<br />

cooling system<br />

Switch supply unit off and on again<br />

Switch drive controller off and on again<br />

Check encoder function and mounting (motor encoder<br />

and external encoder))<br />

4 2 3 1<br />

1 3 2<br />

1 3 2<br />

1 3 2<br />

C0124 C0124 Motor encoder unknown 4 2 3 1<br />

C0125 C0125 Error when reading encoder data<br />

=> optional encoder<br />

C0126 C0126 Incorrect parameterization of<br />

optional enc. (hardware)<br />

C0127 C0127 Incorr. parameteriz. of opt. enc.<br />

(mechanical system)<br />

C0128 C0128 Modulo value for optional encoder<br />

cannot be displayed<br />

4 3 2 1<br />

1 3 2<br />

1 3 2<br />

1 3 2<br />

C0129 C0129 Optional encoder unknown 4 3 2 1<br />

C0130 C0130 Maximum travel range cannot be<br />

displayed internally<br />

1 3 2<br />

C0131 C0131 Switching to phase 3 impossible 1 3 2<br />

C0132 C0132 Invalid settings for controller cycle<br />

times<br />

C0134 C0134 Invalid motor data in encoder<br />

memory (->S-0-0021)<br />

C0135 C0135 Type of construction of motor P-0-<br />

4014 incorrect<br />

C0136 C0136 Several motor encoders<br />

connected<br />

C0137 C0137 Error during initialization of motor<br />

data (->S-0-0021)<br />

C0138 C0138 Invalid control section data (->S-0-<br />

0021)<br />

C0139 C0139 T2 (S-0-0089)+length MDT (S-0-<br />

0010)>TScyc (S-0-0002)<br />

1 3 2<br />

4 5 2 3 1<br />

4 5 2 3 1<br />

1 2<br />

4 5 2 3 1<br />

2 1<br />

1 3 2<br />

C0140 C0140 Rotary scaling not allowed 1 3 2<br />

Check encoder cabling<br />

Check motor cabling<br />

Check wiring of inputs and outputs and their 24V<br />

power supply<br />

Check connection of master communication<br />

Check control circuit for mains connection<br />

Check mechanical system (stiffness, loose<br />

connection,...)