7-44 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

There is important control information defined in the master control word,<br />

like for example:<br />

• drive enable<br />

• <strong>Drive</strong> Halt<br />

• selection of command operating mode<br />

See also Functional Description "Device Control (Status Machine)"<br />

See also Functional Description "System Overview - Master<br />

Communication - SERCOS interface"<br />

See also Functional Description "<strong>Drive</strong> Functions – <strong>Drive</strong> Halt"<br />

S-0-0135, <strong>Drive</strong> status word<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

For drives with SERCOS interface the master status word is cyclically<br />

transmitted from drive to master. There is important status information<br />

contained in the master status word, like for example:<br />

• readiness for operation of control and power sections<br />

• drive error<br />

• change bits class 2 and 3 diagnostics<br />

• current operating mode<br />

See also Functional Description "Device Control (Status Machine)"<br />

See also Functional Description "System Overview - Master<br />

Communication - SERCOS interface"<br />

See also Functional Description "<strong>Drive</strong> Functions – <strong>Drive</strong> Halt"<br />

S-0-0140, Controller type<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

The power section type is contained in the operating data of this<br />

parameter in the form of a text (e.g. <strong>HCS02.1</strong>).<br />

See also Functional Description "Controller Design"<br />

S-0-0141, Motor type<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

The type designation of the motor is entered in this parameter.<br />

See also Functional Description "Motor, Mechanical Axis System,<br />

Measuring Systems"<br />

S-0-0142, Application type<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

DOK-INDRV*-FU*********-IB01-EN-P