6-52 Mounting and Installation <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

X13, Control Voltage (+24 V, 0 V)<br />

The external 24V supply is applied via connection X13 for<br />

• the power section of the drive controller<br />

• brake control via X6 and<br />

• the control section of the drive controller<br />

With regard to control voltage supply, the <strong>HCS02.1</strong> drive controllers are<br />

available in two different designs.<br />

• Standard design <strong>HCS02.1</strong>E-W****-***N:<br />

The control voltage is supplied by an external 24V power supply unit.<br />

• Optional design <strong>HCS02.1</strong>E-W****-***V:<br />

The control voltage is supplied by an integrated 24V power supply unit.<br />

A power supply unit that makes available the control voltage supply for the<br />

power section and the control section from the DC bus is integrated in the<br />

drive controller.<br />

Note: • Falling short of the permissible control voltage leads to a<br />

corresponding error message (=> refer also to firmware<br />

function description).<br />

• Interruption to the control voltage when the motor is<br />

running leads to torque-free (brakeless) runout in the motor.<br />

Note on design -***V:<br />

• The brake supply has to be realized via an external power supply unit.<br />

• Applying the external supply voltage for the purpose of buffering at nopower<br />

operation is allowed.<br />

• Load at the terminal X13 is not allowed.<br />

DANGER<br />

Dangerous movement caused by brakeless<br />

motor coasting to stop in the event of an<br />

interruption to the control voltage supply!<br />

⇒ Do not stay within the motional range of the<br />

machine. Possible measures to prevent personnel<br />

from accidentally accessing the machine:<br />

– protective fencing<br />

– protective grid<br />

– protective cover<br />

– light barrier.<br />

⇒ Fencing and covers must be adequately secured<br />

against the maximum possible force of movement.<br />

DOK-INDRV*-FU*********-IB01-EN-P