7-72 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

Function<br />

Function<br />

This parameter displays the current states of the digital inputs. This<br />

means that the current signal level or switch status (only for MP*02VRS!)<br />

is displayed.<br />

The table below illustrates the different significance of the individual bits<br />

depending on control section and firmware:<br />

P-0-0304, Digital I/Os, outputs<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter displays the states of the digital outputs and relay outputs.<br />

This means that the current signal level or switch status is displayed; the<br />

following cases have to be distinguished for inputs/outputs that can be<br />

switched:<br />

• With configuration as output, the output signal status is displayed in<br />

P-0-0304.<br />

• With configuration as input, the input signal status is displayed in<br />

P-0-0303, Digital I/Os, inputs.<br />

Note: Configuration takes place via P-0-0302, Digital I/Os,<br />

direction.<br />

See also Functional Description "Digital Inputs/Outputs"<br />

P-0-0414, Analog Output 3<br />

Input min/max: Default value: Unit:<br />

MPB: -10,000 / 10,000 0,000 V<br />

This parameter indicates the voltage value that is output via the analog<br />

output 3 of the drive controller.<br />

See also Functional Description "Analog Outputs"<br />

P-0-0415, Analog Output 4<br />

Input min/max: Default value: Unit:<br />

MPB: -10,000 / 10,000 0,000 V<br />

This parameter indicates the voltage value that is output via the analog<br />

output 4 of the drive controller.<br />

See also Functional Description "Analog Outputs"<br />

P-0-0416, Analog Output 5<br />

Input min/max: Default value: Unit:<br />

MPB: -10,000 / 10,000 0,000 V<br />

This parameter displays the voltage value that is output via the analog<br />

output 5 of the drive controller.<br />

DOK-INDRV*-FU*********-IB01-EN-P