<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-79<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

By means of this parameter the proportional gain of the voltage loop is<br />

entered. The voltage loop is used to control the motor voltage in the fieldweakening<br />

range.<br />

Note:<br />

Writing the correct value to this parameter:<br />

• In the case of MAD and MAF with encoder data memory<br />

automatically during initial commissioning.<br />

• In the case of 2AD, ADF, linear and rotary kit motors, by<br />

loading the motor parameters with the commissioning<br />

software (e.g. IndraWorks).<br />

• In the case of other motors: default value or manual input.<br />

See also Functional Description "Third-Party Motors at <strong>Indra<strong>Drive</strong></strong><br />

<strong>Controllers</strong>"<br />

P-0-0534, Voltage loop integral action time<br />

Input min/max: Default value: Unit:<br />

MPB: 0,0 / 429496729,5 600,0 ms<br />

By means of this parameter the integral action time of the voltage loop is<br />

entered. The voltage loop is used to control the motor voltage in the fieldweakening<br />

range.<br />

Note:<br />

Writing the correct value to this parameter:<br />

• In the case of MAD and MAF with encoder data memory<br />

automatically during initial commissioning.<br />

• In the case of 2AD, ADF, linear and rotary kit motors, by<br />

loading the motor parameters with the commissioning<br />

software (e.g. IndraWorks).<br />

• In the case of other motors: default value or manual input.<br />

See also Functional Description "Determining the Motor Parameter<br />

Values"<br />

P-0-0535, Motor voltage at no load<br />

Input min/max: Default value: Unit:<br />

MPB: 0,0 / 100,0 80,0 %<br />

As a matter of principle, this parameter only takes effect in field<br />

weakening operation. It defines a voltage that is indicated in percent of<br />

the maximum converter output voltage.<br />

See also Functional Description "Determining the Motor Parameter<br />

Values"<br />

P-0-0536, Maximum motor voltage<br />

Input min/max: Default value: Unit: