<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-99<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

This parameter is used to control the drive in the following cases:<br />

• for devices with analog or parallel master communication<br />

• When the drive is switched to the "easy startup mode" via the control<br />

panel.<br />

Note: In the case of master communication via field bus or<br />

SERCOS, P-0-4077, Field bus: control word and S-0-0134,<br />

Master control word are used accordingly for controlling the<br />

drive!<br />

See also Functional Description "Master Communication"<br />

See also Functional Description "Operating Modes"<br />

P-0-4031, Overview of device addresses<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter is used to display the following addresses in clearly<br />

structured and holistic form which is particularly important for multi-axis<br />

devices:<br />

• effective drive address of master communication that was set via<br />

parameter P-0-4025<br />

• effective drive address of serial interface that was set via parameter<br />

P-0-4022<br />

Note: Especially for multi-axis devices (e.g. HMD01.1) the parameter<br />

P-0-4031 provides a clear overview as regards the axis<br />

addresses effective in the device.<br />

P-0-4032, Motor type plate data<br />

Input min/max: Default value: Unit:<br />

MPB: 0,000 / 250000,000 --- --<br />

For asynchronous third-party motors it is possible via C3200 Command<br />

Calculate motor data to calculate the values for motor parameters from<br />

the type plate data and then the values of the motor control parameters.<br />

The activation of C3200 first requires manual input of the motor data from<br />

the type plate of the asynchronous motor in the list parameter P-0-4032,<br />

Motor type plate data.<br />

Note: When a <strong>Rexroth</strong> motor is used, the content of P-0-4032 and<br />

the command C3200 are irrelevant as for these motors all<br />

parameters required for operation are stored in the data base<br />

for motor data (<strong>Drive</strong>Base).<br />

See also Functional Description "Automatic Setting of Motor Control<br />

Parameters"<br />

P-0-4033, C3200 Command Calculate motor data<br />

Input min/max: Default value: Unit: