<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-107<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

parameters that are not linked to a real-time cycle. In the case of<br />

PROFIBUS, for which not all control units are supporting acyclic access,<br />

these data can be exchanged via a parameter channel.<br />

See also Functional Description "PROFIBUS-DP"<br />

P-0-4084, Field bus: profile type<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 0xFF82 --<br />

The setting of P-0-4084, Field bus: profile type influences<br />

• the profile-dependent interpretation of the control and status words<br />

• the preselection of the primary mode of operation set in the drive<br />

• the configuration of the real-time data channel (unless freely<br />

configurable).<br />

See also Functional Description "PROFIBUS-DP"<br />

P-0-4085, C4700 Command Activate easy startup mode<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter is used for activating the easy startup mode via the serial<br />

interface. With the start of this command the drive switches master<br />

communication (SERCOS or Profibus) off. The drive automatically<br />

switches to the parameter mode, makes the parameter setting for the<br />

"easy startup mode" and switches to the operating mode. The parameter<br />

setting is stored in volatile form. The easy startup mode can only be<br />

deactivated by switching control voltage off and on.<br />

P-0-4086, Master communication status<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter contains important status information regarding the<br />

current status of master communication or device control. Independent<br />

thereof some control information for handling the communication phase<br />

switch, as well as for enabling the hardware inputs for drive enable and<br />

<strong>Drive</strong> Halt, is controlled.<br />

Note: Users cannot write this parameter, it is only used for<br />

diagnostic purposes.<br />

See also Functional Description "Initial Start in "Easy Startup" Mode"<br />

See also Functional Description "Device Control (Status Machine)"<br />

See also Functional Description "Master Communication"<br />

P-0-4090, Configuration for loading default values<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --