6-54 Mounting and Installation <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Design<br />

Tightening Torque<br />

Multiple-Line Arrangement<br />

The control voltage supply is routed to the connection X13 from above<br />

(see following figure).<br />

1: lines to control voltage supply<br />

Fig. 6-77: Control voltage supply at X13<br />

Optional Control Voltage (HCS03)<br />

Control voltage is supplied by an external 24V power supply unit.<br />

Note: Technical data of control voltage: see section "Electrical Data"<br />

The control voltage supply is connected via contact bars and screws (M6)<br />

at the front of the drive controller. Depending on the width of the drive<br />

controllers, there are contact bars of different lengths.<br />

6 Nm<br />

The following figures show the correct control voltage connection for<br />

stacked drive controllers. The illustrated way of connection ensures that<br />

the touch guard can be correctly mounted and the required clearances<br />

and creepage distances can be complied with.<br />

The cables have to be twisted. Observe the notes in chapter "Arranging<br />

the Components in the Control Cabinet", section "Installing the 24V<br />

Supply".<br />