6-82 Mounting and Installation <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

PE<br />

PE<br />

PE<br />

X3 L3<br />

L2<br />

L1<br />

Shield Connection of Power<br />

Supply Cable HAS02.1-007-NNN-<br />

NN with Mains Filter Mounted<br />

L1 L2 L3 PE<br />

shielding plate<br />

support<br />

clip<br />

MBZU0013EN01.FH9<br />

Fig. 6-106: Shielding plate HAS02.1-006-NNN-NN at the bottom of the mains<br />

filter (nominal current 50 A)<br />

3. Fix shield of motor cable to shielding plate with a clip.<br />

Note: The shield terminals must not be used to provide strain relief.<br />

1. Hang up support at bottom of mains filter and fasten it by means of<br />

supplied screws.<br />

2. Screw shielding plate of power supply cable to support.<br />

According to required power supply cable routing, it is possible to mount<br />

shielding plate in different positions:<br />

• power supply cable routed in parallel or,<br />

• 45° to bottom of mains filter or,<br />

• 90° to bottom of mains filter.<br />

DOK-INDRV*-FU*********-IB01-EN-P