<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-51<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

Note: Parameter S-0-0822 replaces the previously available filtering<br />

by means of the PT1 filter (cf. P-0-0176)!<br />

See also Parameter Description "S-0-0822, Torque/force ramp"<br />

See also Parameter Description "S-0-0824, Message torque/force<br />

command value reached"<br />

See also Functional Description "Operating Modes - Torque/Force<br />

Control"<br />

S-0-0823, Torque/force ramp time<br />

P-0-0001 – P-0-0689 (General Functions)<br />

Function<br />

Input min/max: Default value: Unit:<br />

MPB: 0,0 / 6553,5 0,0 ms<br />

The torque/force ramp time (S-0-0823) is the reference time for the<br />

torque/force ramp. In the operating mode torque/force control, the<br />

parameter S-0-0823, together with the torque/force ramp (S-0-0822),<br />

defines an increase for the torque/force command value (S-0-0080).<br />

See also Parameter Description "S-0-0822, Torque/force ramp"<br />

See also Parameter Description "S-0-0824, Message torque/force<br />

command value reached"<br />

See also Functional Description "Operating Modes - Torque/Force<br />

Control"<br />

S-0-0824, Message torque/force command value reached<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

In the operating mode "torque/force control", the message "S-0-0824,<br />

Message torque/force command value reached" indicates that the<br />

internal "S-0-0080, Torque/force command value" has reached the<br />

preset value.<br />

See also Functional Description "Operating Modes"<br />

P-0-0001, Switching frequency of the power output stage<br />

Input min/max: Default value: Unit:<br />

MPB: 4000 / 8000 4000 Hz<br />

The switching frequency of the power output stage can be set. The max.<br />

switching frequency is determined by P-0-4058, Amplifier type data, list<br />

element 16. Depending on the device type, the following values can be<br />

set, for example:<br />

Device type / switching frequ. fs [kHz] 2 4 8 12 16<br />

HCS02 O X X X X<br />

HCS03 O X X X X