5-14 Electrical Data <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Analog Output Type 3<br />

Data Unit Min. Typ. Max.<br />

output voltage V -10 +10<br />

output load kOhm 1<br />

output current mA 0 +1<br />

converter width digital/analog<br />

converter incl. polarity sign<br />

Bit 12<br />

resolution mV/Ink 5<br />

accuracy at R = 1 kOhm % 1 of FMR<br />

accuracy at R = 10 kOhm % 0,2 of FMR<br />

conversion time<br />

(incl. response time)<br />

us 10<br />

cyclic conversion us depending on firmware<br />

short circuit protection present<br />

overload protection present<br />

FMR: final value of measuring range<br />

Fig. 5-23: Analog outputs type 3<br />