7-96 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

potentiometer. This value is then processed in the ramp generator and<br />

transmitted to P-0-0048, Effective velocity command value.<br />

Note: The value of parameter P-0-1218 is stored in case the control<br />

voltage fails so that it is possible to reuse the value.<br />

See also Functional Description "Operating Modes - Velocity Control"<br />

P-0-1222, Velocity command filter<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / 16 0 ms<br />

This parameter is used to round acceleration jumps in the velocity<br />

command value characteristics in order to have a smooth initialization or<br />

deceleration of the drive in velocity control.<br />

See also Functional Description "Velocity Command Value Reset with<br />

Filter and Ramp (Quick Stop)"<br />

P-0-1500 – P-0-1599 (General Device Parameters)<br />

Function<br />

P-0-1520, Control section type<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter displays the type designation of the control section. By<br />

means of circuit board code parameters the controller firmware identifies<br />

all circuit boards incorporated in the control section and thus generates<br />

the type designation.<br />

The type designation of the control section also implies firmware<br />

dependencies.<br />

P-0-2000 – P-0-2999 (General Device Parameters<br />

Function<br />

P-0-2004, Active functional packages<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

his parameter contains the active functional packages.<br />

When booting the functional packages selected in P-0-2003 are activated<br />

and then the respective bits are set or cleared in P-0-2004. This allows<br />

recognizing at any time which functional packages are actually active.<br />

Note: This parameter can neither be written nor stored. It is for<br />

display only.<br />

See also Functional Description "Enabling of Functional Packages"<br />

See also Functional Description "Functional Packages"<br />