02.02.2013 Views

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-101<br />

Function<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

P-0-4040, Rotor leakage inductance<br />

Input min/max: Default value: Unit:<br />

MPB: 0,001 / 4294967,295 5,000 mH<br />

This parameter is only used for operating asynchronous motors and takes<br />

effect for current control of the motor.<br />

For <strong>Rexroth</strong> motors this value is stored in the <strong>Drive</strong>Base.<br />

For third-party motors this parameter is calculated via the command<br />

C3200 Command Calculate data for asynchronous motor that is<br />

started with P-0-4033.<br />

P-0-4041, Motor magnetizing inductance<br />

Input min/max: Default value: Unit:<br />

MPB: 0,010 / 4294967,295 50,000 mH<br />

This parameter is only used for operating asynchronous motors and takes<br />

effect for current control of the motor.<br />

For <strong>Rexroth</strong> motors this value is stored in the <strong>Drive</strong>Base. For third-party<br />

motors this parameter is calculated via the command C3200 Command<br />

Calculate data for asynchronous motor that is started with P-0-4033.<br />

See also Functional Description "Determining the Motor Parameter<br />

Values"<br />

P-0-4042, Characteristic of motor magnetizing<br />

inductance<br />

Input min/max: Default value: Unit:<br />

MPB: 0,500 / 2,000 --- --<br />

This list parameter is only used for operating asynchronous motors and<br />

takes effect for current control of the motor.<br />

• For <strong>Rexroth</strong> motors the characteristic values are made available by<br />

the manufacturer, either by means of a data sheet or the<br />

commissioning software (e.g. IndraWorks).<br />

• For third-party motors the characteristic in the majority of cases is<br />

unknown. Via the command C3200 Command Calculate data for<br />

asynchronous motor that is started with P-0-4033 the list is neutrally<br />

assigned.<br />

• Via the command C3600 Command Motor data identification that is<br />

started with P-0-0565 the characteristic of the asynchronous motor is<br />

determined and entered in this list.<br />

See also Functional Description "Motor Control"<br />

P-0-4043, Rotor time constant<br />

Input min/max: Default value: Unit:<br />

MPB: 0,100 / 10000,000 100,000 ms<br />

This parameter is only active for asynchronous motors. It has a<br />

considerable influence on the torque generation of the motor, as it<br />

decisively determines the so-called "slip" in the case of load.