7-38 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

Function<br />

Function<br />

MPB: --- S-0-0044<br />

Depending on the application, this parameter indicates the value for the<br />

maximum allowed positive velocity command value of the motor.<br />

See also Functional Description "Velocity Limitation"<br />

S-0-0039, Negative velocity limit value<br />

Input min/max: Default value: Unit:<br />

MPB: --- S-0-0044<br />

Depending on the application, this parameter indicates the value for the<br />

maximum allowed negative velocity command value of the motor.<br />

See also Functional Description "Velocity Limitation"<br />

S-0-0040, Velocity feedback value<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- S-0-0044<br />

The actual velocity value of the motor encoder can be transmitted by the<br />

drive controller to the control unit either cyclically or via the service<br />

channel.<br />

Note: In open-loop operation, parameter S-0-0040 contains the<br />

actual velocity value estimated by means of a motor model.<br />

See also Functional Description "Operating Modes - Velocity Control"<br />

S-0-0044, Velocity data scaling type<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 2 --<br />

The scaling type of the velocity data determines in which format and<br />

which reference the velocity data are exchanged between the drive and<br />

the control unit or user interface.<br />

See also Functional Description "Scaling of Physical Data"<br />

S-0-0082, Torque/force limit value positive<br />

Input min/max: Default value: Unit:<br />

MPB: 400,0 S-0-0086<br />

This parameter allows determining a torque or force limit value for<br />

positive torque/force command values. This limit value only takes effect<br />

with regard to the torque command value of the velocity controller<br />

(P-0-0049) and not with regard to command values from the acceleration<br />

feedforwards (S-0-0348, P-0-1126). Positive torque takes effect in the<br />

case of:<br />

• motive operation at positive velocity<br />

DOK-INDRV*-FU*********-IB01-EN-P