7-120 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Temperature Scaling<br />

Further Settings for Parameter<br />

Scaling<br />

WARNING<br />

Danger of incorrect actual position value of<br />

encoders evaluated in absolute form after<br />

switching the drive on, when the mechanical<br />

drive system, with the drive switched off, was<br />

moved in the case of modulo scaling!<br />

Make sure that the mechanical drive system, with the<br />

⇒<br />

drive switched off, is as a maximum moved by a<br />

distance or angle corresponding to half the absolute<br />

encoder range (S-0-0378, Absolute encoder range<br />

of motor encoder or S-0-0379, Absolute encoder<br />

range of optional encoder)!<br />

In addition, make the scaling setting for temperature data in parameter<br />

S-0-0208, Temperature data scaling type.<br />

Individual Settings for Parameter Scaling<br />

position data:<br />

• S-0-0077, Linear position data scaling factor position data<br />

• S-0-0078, Linear position data scaling exponent<br />

- or -<br />

• S-0-0079, Rotational position resolution<br />

velocity data:<br />

• S-0-0045, Velocity data scaling factor<br />

• S-0-0046, Velocity data scaling exponent<br />

acceleration data:<br />

• S-0-0161, Acceleration data scaling factor<br />

• S-0-0162, Acceleration data scaling exponent<br />

Diagnostic Messages of Scaling Setting<br />

If inadmissible scaling settings were made, they are detected when<br />

switching from parameter mode (communication phase 2) to operating<br />

mode (communication phase 4). The drive in this case does not reach the<br />

operating mode and, according to setting, displays the following<br />

command errors:<br />

• C0122 Incorr. parameteriz. of motor enc. (mechanical system)<br />

• C0123 Modulo value for motor encoder cannot be displayed<br />

• C0127 Incorr. parameteriz. of opt. enc. (mechanical system)<br />

• C0128 Modulo value for optional encoder cannot be displayed<br />

• C0140 Rotary scaling not allowed<br />

• C0101 Invalid parameters (see S-0-0021)<br />

• C0102 Limit error in parameter (-> S-0-0021)<br />

• C0103 Parameter conversion error (->S-0-0021)<br />

Example of Scaling Settings<br />

There are many possibilities to make settings for the scaling type. The<br />

table below shows useful settings for which there aren't any command<br />

errors to be expected:<br />

DOK-INDRV*-FU*********-IB01-EN-P