7-80 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

Function<br />

MPB: 50,0 / 100,0 90,0 %<br />

This parameter defines the command voltage of the voltage loop. It is<br />

indicated in percent of the maximum converter output voltage.<br />

Note:<br />

Writing the correct value to this parameter:<br />

• In the case of MAD and MAF with encoder data memory<br />

automatically during initial commissioning.<br />

• In the case of 2AD, ADF, linear and rotary kit motors, by<br />

loading the motor parameters with the commissioning<br />

software (e.g. IndraWorks).<br />

• In the case of other motors: Default value or manual input,<br />

set a maximum of 90% because of the required control<br />

margin!<br />

See also Functional Description "Third-Party Motors at <strong>Indra<strong>Drive</strong></strong><br />

<strong>Controllers</strong>"<br />

P-0-0539, Holding brake status word<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter displays the current status of the holding brake.<br />

See also Functional Description "Motor Holding Brake"<br />

P-0-0542, C2000 Command Release motor holding brake<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

By means of this parameter it is possible to release the motor holding<br />

brake when the drive enable has been switched off. At the start of the<br />

command the motor holding brake is released, when the command is<br />

terminated the brake is applied again.<br />

If drive enable is set with the command being active, the holding brake<br />

remains released, when drive enable is switched off, the brake is<br />

automatically applied.<br />

Note: The command has to be activated via bit 5 in P-0-0525,<br />

Holding brake control word.<br />

See also Functional Description "Motor Holding Brake"<br />

P-0-0551, Current load torque<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- S-0-0086<br />

In this parameter, the maximum occurring load torque of the axis in<br />

standstill is displayed and cyclically compared to P-0-0547, Nominal load<br />

DOK-INDRV*-FU*********-IB01-EN-P