<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Diagnostic and Service Functions 8-17<br />

Display at comfort control panel<br />

S-0-0095, Diagnostic message text<br />

E8040 E8040 Torque/force actual value limit<br />

active<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

See documentation "Troubleshooting Guide"<br />

Contact our sales and service facility<br />

Contact machine manufacturer / installation<br />

programmer<br />

Check motor incl. holding brake, battery, encoder and<br />

cooling system<br />

Switch supply unit off and on again<br />

Switch drive controller off and on again<br />

Check encoder function and mounting (motor encoder<br />

and external encoder))<br />

Check encoder cabling<br />

Check motor cabling<br />

Check wiring of inputs and outputs and their 24V<br />

power supply<br />

2 1<br />

E8041 E8041 Current limit active 4 2 3 1<br />

E8043 E8043 Positive travel range limit switch<br />

activated<br />

E8044 E8044 Negative travel range limit switch<br />

activated<br />

2 1<br />

2 1<br />

E8055 E8055 Motor overload, current limit active 5 3 4 2 1<br />

E8057 E8057 Device overload, current limit<br />

active<br />

E8058 E8058 <strong>Drive</strong> system not ready for<br />

operation<br />

E8260 E8260 Torque/force command value limit<br />

active<br />

1 2<br />

F2005 F2005 Cam shaft invalid 1 3 2<br />

F2006 F2006 MMC was removed 1 2<br />

F2007 F2007 Switching to non-initialized<br />

operating mode<br />

RL F2008 RL The motor type has changed. 1<br />

PL F2009 PL Load parameter default values 1<br />

F2010 F2010 Error when initializing digital<br />

inputs/outputs<br />

5 3 4 2 1<br />

2 1<br />

1 3 2<br />

1 3 2<br />

F2011 F2011 PLC - Error nr. 1 2 1<br />

F2012 F2012 PLC - Error nr. 2 2 1<br />

F2013 F2013 PLC - Error nr. 3 2 1<br />

F2014 F2014 PLC - Error nr. 4 2 1<br />

F2018 F2018 Device overtemperature shutdown 3 2 1<br />

F2019 F2019 Motor overtemperature shutdown 5 3 4 2 1<br />

F2021 F2021 Motor temperature monitor<br />

defective<br />

F2022 F2022 Device temperature monitor<br />

defective<br />

4 2 3 1<br />

2 1<br />

F2026 F2026 Undervoltage in power section 1 4 3 2<br />

F2028 F2028 Excessive deviation 2 3 1<br />

F2031 F2031 Encoder 1 error: signal amplitude<br />

incorrect<br />

F2032 F2032 Validation error during<br />

commutation fine adjust<br />

3 4 2 1<br />

F2033 F2033 External power supply X10 error 2 3 1<br />

F2036 F2036 Excessive position feedback<br />

difference<br />

2 5 4 3 1<br />

Check connection of master communication<br />

Check control circuit for mains connection<br />

Check mechanical system (stiffness, loose<br />

connection,...)