8-28 Diagnostic and Service Functions <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Selection Criterion<br />

Firmware Upgrade with<br />

IndraWorks D<br />

3. Check safety technology parameters (only when safety technology<br />

has been activated in drive)<br />

In the case of a release update, safety technology parameters are<br />

retained. With safety technology activated, the following steps are<br />

additionally required:<br />

Check whether correct safety technology parameters for drive are still<br />

⇒<br />

available.<br />

To do this, check the following points:<br />

• data in P-0-3205, Safety technology device identifier<br />

• status of safety technology via P-0-3207, Safety technology<br />

password level (in the case of active and locked safety<br />

technology, level is 2)<br />

• change counter of safety technology memory (P-0-3201, Change<br />

counter of safety technology memory)<br />

• operating hours at last change of memory (P-0-3202, Operating<br />

hours at last change of memory)<br />

Variant 2: Release Update with IndraWorks D<br />

The following requirements should have been fulfilled in order that<br />

carrying out the firmware release update with IndraWorks D makes<br />

sense:<br />

• Controller is operated without MMC.<br />

- or -<br />

• Controller has been equipped with BASIC single-axis control section.<br />

Carrying out the firmware release update with IndraWorks D requires the<br />

following steps:<br />

1. Load firmware<br />

Call IndraWorks D.<br />

⇒<br />

Load project for corresponding axis or create new project; to do this,<br />

⇒<br />

address axis via a serial connection.<br />

Switch project "online".<br />

⇒<br />

Select/highlight controller and call "Firmware management" in context<br />

⇒<br />

menu.<br />

→A new window opens and firmware currently available in drive is<br />

displayed on its right side. On left side of window, firmware available<br />

in current firmware directory is displayed.<br />

Highlight new firmware (*.ibf file) on left side and start firmware<br />

⇒<br />

download via "Download" button.<br />

→ Firmware download runs automatically and all required firmware<br />

components are loaded to drive.<br />

After firmware download has been completed, close "Firmware<br />

⇒<br />

management" window.<br />

2. Put machine into ready-for-operation status<br />

Put machine into ready-for-operation status again according to<br />

⇒<br />

machine manufacturer's instructions.<br />

Check functions of drive.<br />

⇒<br />