<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-43<br />

Function<br />

Function<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

This parameter displays the maximum possible continuous current of the<br />

drive.<br />

Note: In the case of rotary field frequencies smaller than 3 Hz, the<br />

possible amplifier continuous current is reduced by means of a<br />

temperature model (see Technical Data in hardware Project<br />

Planning Manual!).<br />

See also Functional Description "Current Limitation"<br />

S-0-0113, Maximum motor speed<br />

Input min/max: Default value: Unit:<br />

MPB: 3000,0000 S-0-0044<br />

Value for the maximum allowed velocity command value of the motor.<br />

The actual velocity value may be a maximum of 12.5% higher than the<br />

value of S-0-0113, with higher actual values the drive reacts with torque<br />

disable and generates the error message F8079 Velocity limit S-0-0091<br />

exceeded.<br />

See also Functional Description "Limitations"<br />

S-0-0127, C0100 Communication phase 3 transition<br />

check<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

When executing the S-0-0127, C0100 Communication phase 3<br />

transition check command, all interface parameters are checked for<br />

validity.<br />

See also Functional Description "Device Control (Status Machine)"<br />

S-0-0128, C5200 Communication phase 4 transition<br />

check<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

When executing the command S-0-0128, C0200 Communication phase<br />

4 transition check is executed, all parameters are checked for validity<br />

and possible limit value violations.<br />

See also Functional Description "Device Control (Status Machine)"<br />

S-0-0134, Master control word<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

For drives with SERCOS interface the master control word is cyclically<br />

transmitted from master to drive.