02.02.2013 Views

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Mounting and Installation 6-53<br />

Design<br />

Connection Cross Section<br />

Connection<br />

Load Capacity<br />

Lines +24 V and 0 V<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

Type Number of poles Type of design<br />

Spring power 4 Pins on connector<br />

Fig. 6-72: Design<br />

Cross section<br />

single-wire<br />

[mm²]<br />

Cross section<br />

multi-wire<br />

[mm²]<br />

Cross section<br />

in AWG<br />

0.14-1.5 0.14-1.5 28-16<br />

Fig. 6-73: Connection Cross Section<br />

3, 4 +24 V<br />

1, 2 0 V<br />

Fig. 6-74: Identification of the individual connections<br />

looping through the power supply up to max. 6 Aeff allowed<br />

polarity reversal protection over the allowed voltage range by<br />

internal protective diode of +24V<br />

circuit<br />

Fig. 6-75: Load capacity<br />

Note: The input 0 V connected in conductive form with the housing<br />

potential. It is therefore impossible to use an insulation monitor<br />

at +24 V and 0 V against housing.<br />

line cross section min. 1 mm²<br />

line routing preferably in parallel<br />

max. allowed inductance between 24V<br />

supply source and X13<br />

Fig. 6-76: Supply line 24 V<br />

100 µH<br />

(corresponds to approx. 2*75 m)