8-26 Diagnostic and Service Functions <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Requirements<br />

Loading Firmware to MMC<br />

CSH0x.x<br />

CDB0x.x<br />

MMC<br />

as active<br />

memory?<br />

yes<br />

MMC plugged in<br />

operation<br />

® MMC with old<br />

firmware<br />

Request new<br />

firmware (ibf file)!<br />

Load new firmware<br />

to MMC!<br />

MMC with new<br />

firmware<br />

Release Update<br />

with MMC<br />

no<br />

Control section<br />

type ?<br />

Firmware update<br />

without PC?<br />

yes<br />

Request MMC with<br />

new firmware!<br />

Variant 1 Variant 2<br />

no<br />

CSB0x.x<br />

Request new<br />

firmware (ibf file)!<br />

Release Update<br />

with IndraWorks D<br />

DC000032v01_en.fh<br />

CSH0x.x: ADVANCED single-axis control section<br />

CDB0x.x: BASIC double-axis control section<br />

CSB0x.x: BASIC single-axis control section<br />

active memory: "programming module" operation of MMC (see P-0-4065)<br />

Fig. 8-2: Schematic sequence of firmware release update<br />

Note: The action instructions marked with dark background in the<br />

illustration are described in the paragraphs below.<br />

Loading New Firmware to MMC<br />

The following requirements must have been fulfilled for loading firmware<br />

to the MMC of the drive:<br />

• new firmware available (ibf file)<br />

• PC with MMC reader<br />

• MMC with old firmware in drive<br />

The following steps are required for loading the firmware to the MMC:<br />

1. Switch drive off and remove MMC.<br />

2. Plug MMC into MMC reader and open folder "Firmware" on MMC.<br />

3. Delete old firmware (e.g. FWA-INDRV_-MPH-04V06-D5.ibf).<br />

4. Copy new firmware (e.g. FWA-INDRV_-MPH-04V08-D5.ibf) to folder<br />

"Firmware".<br />