<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Electrical Data 5-3<br />

CSB01.1N-FC… IEIN3 A 1,5 (pulse width tEIN3lade ca. 120 ms)<br />

CSB01.1N-PB… IEIN3 A 5 (pulse width tEIN3lade ca. 40 ms)<br />

Power consumption of optional modules according to type code 3), 4)<br />

C PN3 W 1,0<br />

EN1 PN3 W 6,0<br />

EN2 PN3 W 5,5<br />

ENS PN3 W 5,5<br />

MA1 PN3 W 2,0<br />

MD1 PN3 W 1,0<br />

S PN3 W 1,0<br />

Power Voltage Supply- Mains Connection<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

1) plus control section with optional modules<br />

2) plus optional modules<br />

3) code from the control section type code<br />

4) at max. allowed output load without circuits to be supplied externally<br />

Fig. 5-2: Control voltage<br />

Designation Symbol Unit <strong>HCS02.1</strong>E HCS03.1E<br />

allowed range of mains input<br />

voltage, three-phase;<br />

TN-S, TN-C, TT mains<br />

allowed range of mains input<br />

voltage, three-phase;<br />

IT mains<br />

allowed range of mains input<br />

voltage, single-phase<br />

ULN<br />

ULN<br />

V<br />

V<br />

3 * AC (200…500)<br />

+-10%<br />

3 * AC (200…230)<br />

+-10%<br />

3 * AC (400…500)<br />

+10% -15%<br />

not allowed<br />

ULN V 1 * AC (200…250) +-10% not allowed<br />

rotary field no rotary field condition<br />

allowed range of mains<br />

frequency<br />

max. allowed mains frequency<br />

change<br />

fLN Hz (50…60) + - 2<br />

d fLN /t Hz/s 2% * fLN<br />

Fig. 5-3: Extended range of power voltage<br />

Note: When using HCS02 and HCS03 devices in the mains voltage<br />

range up to 3 * AC 500 V, make sure the additional<br />

components you use may be operated in this mains voltage<br />

range. NFD mains filters, for example, can only be used up to<br />

3 * AC 480 V.