<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-45<br />

Function<br />

Function<br />

Function<br />

Function<br />

S-0-0201 – S-0-0300<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

A descriptive name (text) for the drive or the axis (e.g. swiveling axis) can<br />

be stored in this parameter.<br />

Note: It does not have any influence on the function.<br />

S-0-0144, Signal status word<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

By means of the signal status word it is possible to transmit signals in real<br />

time from the drive to the control unit.<br />

See also Functional Description "Configurable Signal Status Word"<br />

S-0-0145, Signal control word<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

By means of the signal control word it is possible to transmit signals in<br />

real time from the control unit to the drive.<br />

See also Functional Description "Configurable Signal Control Word"<br />

S-0-0160, Acceleration data scaling type<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 2 --<br />

As described below, it is possible to set different scaling types for the<br />

acceleration data in the drive.<br />

The scaling type of the acceleration data determines in which format and<br />

which reference the acceleration data are exchanged between the drive<br />

and the control unit or user interface. The values of the acceleration data<br />

parameters (e.g. S-0-0138, Bipolar acceleration limit value) are<br />

displayed by the drive with the scaling that has been set. The scaling<br />

setting is normally preset by the control unit.<br />

See also Functional Description "Scaling of Physical Data"<br />

S-0-0201, Motor warning temperature<br />

Input min/max: Default value: Unit:<br />

MPB: 145,0 S-0-0208<br />

If the motor temperature exceeds the motor warning temperature, the<br />

drive sets bit 2 (motor overtemperature warning) in S-0-0012, Class 2<br />

diagnostics and the warning E2051 Motor overtemp. prewarning is<br />

output. In the case of MHD and MKD motors, the drive sets this<br />

parameter to 145 °C, in the case of MKE motors to 125 °C.