7-74 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

Function<br />

By means of this parameter it is possible to assign a parameter IDN to the<br />

analog outputs 1 and 3 of the drive controller. The current parameter<br />

value is output as voltage at the analog output, if the mode of the analog<br />

output in P-0-0427, Control parameter of analog output has been set to<br />

output of assignment A. The output voltage can be made visible with an<br />

oscilloscope, for example.<br />

It is only possible to assign those IDNs that have been entered in the<br />

P-0-0426, Analog output IDN list of assignable parameters list.<br />

See also Functional Description "Analog Outputs"<br />

P-0-0422, Analog output, assignment A, scaling [1/V]<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 0 --<br />

This parameter is used to scale the voltage output by analog output 1 and<br />

3. The unit is determined by the parameter assigned in P-0-0420, Analog<br />

output, assignment A, signal selection.<br />

When assigning parameters with the "binary" display attribute, the number<br />

of the bit to be output at the analog output is defined in this parameter.<br />

When the respective bit has not been set, the output voltage is 0 V. When<br />

the bit has been set, 1 V is output.<br />

See also Functional Description "Analog Outputs"<br />

P-0-0423, Analog output, assignment B, signal selection<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

By means of this parameter it is possible to assign a parameter IDN to the<br />

analog outputs 2 and 4 of the drive controller. The current parameter<br />

value is output as voltage at the analog output, if the mode of the analog<br />

output in P-0-0427, Control parameter of analog output has been set to<br />

output of assignment B. The output voltage can be made visible with an<br />

oscilloscope, for example.<br />

It is only possible to assign those IDNs that have been entered in the<br />

P-0-0426, Analog output IDN list of assignable parameters list.<br />

See also Functional Description "Analog Outputs"<br />

P-0-0425, Analog output, assignment B, scaling [1/V]<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 0 --<br />

This parameter is used to scale the voltage output by analog output 2 and<br />

4. The unit is determined by the parameter assigned in P-0-0423, Analog<br />

output, assignment B, signal selection.<br />

When assigning parameters with the "binary" display attribute, the number<br />

of the bit to be output at the analog output is defined in this parameter.<br />

When the respective bit has not been set, the output voltage is 0 V. When<br />

the bit has been set, 1 V is output.<br />

DOK-INDRV*-FU*********-IB01-EN-P