6-58 Mounting and Installation <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Cable Routing to the Right:<br />

CAUTION<br />

device 1<br />

(DC bus connection)<br />

device 2<br />

(DC bus connection)<br />

Damage caused by voltage arcing!<br />

⇒ Insulate ring terminals and connecting lines with a<br />

heat-shrinkable sleeve. Afterwards only strip the<br />

insulation of the contact surface of the ring terminal.<br />

device 1<br />

(DC bus connection)<br />

device 2<br />

(DC bus connection)<br />

correct incorrect<br />

Fig. 6-81: DC bus connections for cable routing to the right<br />

DC bus nach rechts_1f4.fh7<br />

Connection Point of Equipment Grounding Conductor<br />

and Equipment Grounding Connections<br />

DANGER<br />

Dangerous contact voltage at device housing!<br />

Lethal electric shock!<br />

Connect the drive controller to the equipment<br />

⇒<br />

grounding system via connection X3 (mains).<br />

Ground Connection of Housing<br />

The ground connection of the housing is used to provide functional safety<br />

of the drive controllers and protection against contact in conjunction with<br />

the equipment grounding conductor.<br />

Ground the housings of the drive controllers:<br />

1. Connect the bare metal back panel of the drive controller in<br />

conductive form to the mounting surface in the control cabinet. To do<br />

this use the supplied mounting screws.<br />

2. Connect the mounting surface of the control cabinet in conductive<br />

form to the equipment grounding system.<br />