<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-71<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

Note: Apart from the IDN, the bit number desired for the input or<br />

output (cf. P-0-0301, Digital I/Os, bit numbers) and the<br />

output direction (cf. P-0-0302, Digital I/Os, direction) have to<br />

be defined!<br />

See also Functional Description "Digital Inputs/Outputs"<br />

P-0-0301, Digital I/Os, bit numbers<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter is used to configure the digital inputs/outputs of the<br />

control section.<br />

In P-0-0301, Digital I/Os, bit numbers the desired bit number which is to<br />

be assigned to the digital input or output is indicated for each assigned<br />

parameter (cf. P-0-0300, Digital I/Os, assignment list).<br />

Note: Apart from determining the bit number, the IDN desired for the<br />

output or input has to be defined via P-0-0300, Digital I/Os,<br />

assignment list.<br />

See also Parameter Description "P-0-0300, Digital I/Os, assignment list"<br />

See also Functional Description "Digital Inputs/Outputs"<br />

P-0-0302, Digital I/Os, direction<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter is used to configure the digital inputs/outputs of the<br />

control section.<br />

In parameter P-0-0302, Digital I/Os, direction the desired function<br />

(direction) is indicated for each assigned parameter (cf. P-0-0300, Digital<br />

I/Os, assignment list). This means that parameter P-0-0302 sets the<br />

digital input or output.<br />

• "0" for "input" function<br />

• "1" for "output" function<br />

Note: Apart from determining the "digital I/Os, direction", the desired<br />

IDN and bit number for the output or input has to be defined<br />

via P-0-0300, Digital I/Os, assignment list or P-0-0301,<br />

Digital I/Os, bit numbers.<br />

See also Functional Description "Digital Inputs/Outputs"<br />

P-0-0303, Digital I/Os, status display<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --