<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-31<br />

Load Basic Parameters<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

• Press ▼ key.<br />

Name and unit of parameter are displayed.<br />

Parameter Management<br />

• Go to main screen.<br />

By pressing ◄ key several times you get to main screen. By means of<br />

Esc key, you might possibly have to exit editing mode before.<br />

• Press key ►.<br />

Mode selection is displayed.<br />

• Select Parameter management<br />

• Press key ►.<br />

Parameter mode is automatically displayed. Following display appears:<br />

PM: parameter mode<br />

Fig. 7-26: Display "Load basic parameters"<br />

When drive controller was in status AF (drive enable), following display<br />

appears:<br />

Fig. 7-27: Error message when switching operating mode/parameter mode<br />

Switch off drive enable and repeat procedure.<br />

• Select Load basic parameters.<br />

• ► Press key.<br />

Following display appears:<br />

Fig. 7-28: Load basic parameters