<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Diagnostic and Service Functions 8-31<br />

Requirements<br />

Loading Firmware to MMC<br />

Selection Criterion<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

Saving Parameters<br />

Before firmware upgrade all application-specific parameters must be<br />

saved on a data carrier. Parameter backup can be carried out by means<br />

of:<br />

• commissioning software "IndraWorks D"<br />

→ saving parameter values on external data carrier<br />

- or -<br />

• control master<br />

→ saving parameter values on master-side data carrier<br />

Note: Saving the parameters on the MMC available in the drive is<br />

without effect, as this backup will be deleted during the<br />

firmware upgrade.<br />

Loading New Firmware to MMC<br />

The following requirements must have been fulfilled for loading firmware<br />

to the MMC of the drive:<br />

• new firmware available (ibf file)<br />

• PC with MMC reader<br />

• MMC with old firmware in drive<br />

The following steps are required for loading the firmware to the MMC:<br />

1. Switch drive off and remove MMC.<br />

2. Plug MMC into MMC reader and open folder "Firmware" on MMC.<br />

3. Delete old firmware (e.g. FWA-INDRV*-MPH-03V20-D5.ibf).<br />

4. Copy new firmware (e.g. FWA-INDRV*-MPH-04V08-D5.ibf) to folder<br />

"Firmware".<br />

Note: Only one firmware file may be stored in the folder "Firmware"<br />

on the MMC. With several firmware files, the message<br />

"MMC not correct" appears on the display of the drive after<br />

booting.<br />

5. Remove MMC from MMC reader after writing process has been<br />

completed.<br />

Variant 1: Version Upgrade with MMC (without Safety<br />

Technology)<br />

The following requirements should have been fulfilled in order that<br />

carrying out the firmware version upgrade with MMC makes sense<br />

(without safety technology):<br />

• Controller has not been equipped with BASIC single-axis control<br />

section.<br />

• Optional slot for safety technology has not been equipped with option<br />

"safety technology I/O" (S1).<br />

• Current parameter setting of axis was saved.