02.02.2013 Views

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7-30 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

• Select Change single parameter<br />

• ► Press key.<br />

The following display appears:<br />

Fig. 7-24: Select parameter<br />

• With keys Prog + , ⎺Mon, Enter, ◄, ►, enter desired parameter (see<br />

also example below):<br />

Prog + , ⎺Mon: change setting<br />

Enter, ◄, ►: move cursor to the left or to the right<br />

Fig. 7-25: Enter parameter<br />

• After desired parameter has been entered:<br />

Press Enter key.<br />

• Press Esc key.<br />

• Press key ►.<br />

Value of parameter is displayed.<br />

• Press Esc key.<br />

To display name and unit of parameter:<br />

• Press key ▼.<br />

Name and unit of parameter are displayed.<br />

• Press ◄ key to go to previous display.<br />

Example:<br />

Last parameter displayed was S-0-0383.<br />

Parameter P-0-1222 is to be displayed.<br />

• S → key Prog + → P → key Enter<br />

• 0 → key Enter<br />

• → 0 key Prog + 1 → key ► →<br />

• → 3 key → ⎺Mon → 2 ► key<br />

• 8 → key ⎺Mon → 7 … → key ⎺Mon → 2 → key ►<br />

• → 3 key → ⎺Mon → 2 ► key<br />

• Press Enter key.<br />

• Press Esc key.<br />

• ► Press key.<br />

Value of parameter P-0-1222 is displayed.<br />

• Press Esc key.<br />

DOK-INDRV*-FU*********-IB01-EN-P

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!