02.02.2013 Views

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7-62 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

Function<br />

Function<br />

P-0-0192, Error memory of diagnostic numbers<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

When the drive diagnoses a class 1 diagnostics error, a bit is set in<br />

parameter S-0-0011, Class 1 diagnostics. Bit 13 for "Error in class 1<br />

diagnostics" is then set in the drive status word.<br />

See also Functional Description "Error Memory (Power Section and<br />

Control Section)"<br />

P-0-0193, Error memory operating hours of control<br />

section<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- s<br />

When the drive diagnoses a class 1 diagnostics error, a bit is set in<br />

parameter S-0-0011, Class 1 diagnostics. Bit 13 for "Error in class 1<br />

diagnostics" is then set in the drive status word.<br />

See also Functional Description "Error Memory (Power Section and<br />

Control Section)"<br />

P-0-0194, Error memory power section<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / 4294967295 --- --<br />

When the drive diagnoses a class 1 diagnostics error, a bit is set in<br />

parameter S-0-0011, Class 1 diagnostics. Bit 13 for "Error in class 1<br />

diagnostics" is then set in the drive status word.<br />

See also Functional Description "Error Memory (Power Section and<br />

Control Section)"<br />

P-0-0196, Build date and time<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

The build date and build time of the drive firmware can be read from this<br />

parameter as a text.<br />

See also Functional Description "System Overview"<br />

P-0-0197, System time<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

Parameter P-0-0197 contains a system time of the drive with a resolution<br />

of 100 ns. It can be used in conjunction with the parameters P-0-0198 and<br />

DOK-INDRV*-FU*********-IB01-EN-P

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!