<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-103<br />

Function<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

The parameter P-0-4068, Field bus: control word IO is used as field<br />

bus control word (16 bits) in the I/O mode. We distinguish the two<br />

following profile types with freely expandable real-time data and<br />

configurable field bus status word:<br />

• "I/O mode positioning" (P-0-4084, Field bus: Profile type = 0xFF82)<br />

• "I/O mode preset velocity" (P-0-4084, Field bus: Profile type =<br />

0xFF82)<br />

See also Functional Description "Profile Types - I/O Mode"<br />

P-0-4069, Field bus: module diagnosis<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

Parameter for reading master communication settings and states (with<br />

field buses).<br />

Note: This parameter is only relevant for the development staff! It is<br />

irrelevant for the application side!<br />

See also Functional Description "PROFIBUS-DP"<br />

P-0-4071, Field bus: length of cyclic command value data<br />

channel<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / 32 2 Byte<br />

This parameter indicates the number of bytes of the process data channel<br />

parameterized in P-0-4081, Field bus: config. list of cyclic command<br />

value data ch.<br />

This length does not contain the length parameterized in P-0-4083, Field<br />

bus: length of parameter channel of a possibly available parameter<br />

channel. The graduation takes place in word boundaries, i.e. possible<br />

values are 2, 4, 6, ... 32.<br />

Note: For communication via Interbus it is obligatory, due to the bus<br />

structure (shift register), that P-0-4071 = P-0-4082.<br />

See also Functional Description "PROFIBUS-DP"<br />

P-0-4072, C2900 Command Firmware update from MMC<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

With this command, the firmware is copied from the MultiMediaCard<br />

plugged in the controller to the controller and to possibly available<br />

firmware-carrying additional components.<br />

The command can be started via the control panel or via a commissioning<br />

tool ("IndraWorks D" or "SynTop"). After successful firmware update the<br />

message "End C29" is displayed. The user now has to switch the drive off<br />

and on again so that the new firmware becomes active.