<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Electrical Data 5-9<br />

Analog Inputs/Outputs<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

The analog inputs correspond to IEC 61 131.<br />

Analog Input Type 1<br />

U+<br />

U-<br />

GND<br />

Ru<br />

Ru<br />

AD: analog/digital converter<br />

Fig. 5-13: Analog voltage inputs<br />

AD<br />

DA000025v01_nn.FH9<br />

Data Unit Min. Typ. Max.<br />

allowed input voltage<br />

voltage inputs<br />

input resistance<br />

voltage input<br />

V -10 +10<br />

kOhm 180<br />

input bandwidth kHz 6<br />

common-mode range V -20 +20<br />

common-mode rejection dB<br />

relative measuring error<br />

at 90% Uemax<br />

converter width A/D converter<br />

incl. polarity sign<br />

% -1 +1<br />

Bit 10<br />

oversampling 8-fold<br />

dynamic converter width with<br />

oversampling<br />

Bit 12<br />

resulting resolution mV/Ink 5,5<br />

cyclic conversion us 500 (depending on firmware)<br />

conversion time us n.s.<br />

Fig. 5-14: Analog voltage inputs