02.02.2013 Views

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Diagnostic and Service Functions 8-33<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

Acknowledge this message by pressing "Enter" key of control panel.<br />

⇒<br />

By doing this, firmware is loaded from plugged MMC to controller.<br />

If drive before firmware replacement was operated without MMC<br />

plugged, the following message appears:<br />

• "Load new param.?"<br />

→ Switch drive off, remove MMC and restart drive.<br />

2. Put drive into ready-for-operation status<br />

⇒ As number of parameters to be buffered has changed, "PL" appears<br />

on display (in case errors are present, remove them first). If you now<br />

press "Esc" key, all buffered parameters are set to their default<br />

values. During this time, message "C07 Load default parameters"<br />

appears on display.<br />

3. Load parameter values<br />

Load parameter file which was saved.<br />

⇒<br />

If drive before firmware replacement was operated with MMC<br />

plugged:<br />

→ Switch drive off, remove MMC and restart drive.<br />

4. Complete commissioning of integrated safety technology<br />

Switch drive to operating mode (communication phase 4).<br />

⇒<br />

If drive before firmware replacement was operated without MMC<br />

plugged, error message "F3152 Incorrect backup of safety technology<br />

data" appears as safety technology parameter set between firmware<br />

versions 02, 03 and 04 has changed.<br />

→ Clear error message.<br />

Activate command "synchronize and store safety technology IDN"<br />

⇒<br />

(C3000).<br />

Activate safety technology by inputting safety technology password<br />

⇒<br />

(P-0-3206).<br />

Carry out new acceptance test.<br />

⇒<br />

See sections "Activating the safety technology" and "Acceptance<br />

Test" in the separate documentation "<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong>: Integrated<br />

Safety Technology" (DOK-INDRV*-SI*-**VRS**-FK**-EN-P; part no.<br />

R911297838)<br />

Note: After a firmware version upgrade for drive controllers with<br />

optional safety technology module ("S1"), you have to carry out<br />

a complete acceptance test.<br />

⇒ Make safety technology parameter backup, compile acceptance test<br />

protocol and add it to safety-relevant documentation of machine.<br />

5. Put machine into ready-for-operation status<br />

⇒ Put machine into ready-for-operation status again according to<br />

machine manufacturer's instructions.<br />

⇒ Check functions of drive.