7-36 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

7.3 Overview of Parameters – Base Package<br />

S-0-0000 – S-0-0100<br />

Function<br />

Function<br />

Function<br />

Function<br />

This chapter contains the parameters of firmware MPx-04 which are<br />

relevant for open-loop or closed-loop applications.<br />

S-0-0030, Manufacturer version<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter contains the drive firmware version in the form of a text<br />

(ASCII format).<br />

See also Functional Description "System Overview"<br />

S-0-0032, Primary mode of operation<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 2 --<br />

The operating mode determined in this parameter is activated in the drive,<br />

if:<br />

• the primary mode of operation was selected in the master control word<br />

• (bits 8 and 9 = "00") and<br />

• control and power sections are ready for operation and<br />

• drive enable "RF" was set.<br />

See also Functional Description "Selecting the Operating Mode"<br />

S-0-0033, Secondary operation mode 1<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 2 --<br />

The operating mode determined in this parameter is activated in the drive,<br />

if:<br />

the secondary operating mode 1 was selected in the master control word<br />

(bits 8 and 9 = "01"),<br />

• control and power sections are ready for operation and<br />

• drive enable "RF" was set.<br />

See also Functional Description "Selecting the Operating Mode"<br />

S-0-0034, Secondary operation mode 2<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 2 --<br />

The operating mode determined in this parameter is activated in the drive,<br />

if:<br />

DOK-INDRV*-FU*********-IB01-EN-P