<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-97<br />

P-0-3600 – P-0-4095 (General Device Parameters)<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

P-0-4004, Magnetizing current<br />

Input min/max: Default value: Unit:<br />

MPB: 0,000 / var. 1,000 A eff<br />

In the case of asynchronous motors, the nominal magnetizing current<br />

defined by <strong>Bosch</strong> <strong>Rexroth</strong> is entered in this parameter. The actually<br />

flowing magnetizing current in the base speed range results by<br />

multiplication of the value of P-0-4004 with P-0-0532, Premagnetization<br />

factor. In the field weakening range the magnetizing current, with<br />

increasing speed, is reduced by the flux loop based on the value of this<br />

product.<br />

Note:<br />

Writing the correct value to this parameter:<br />

• In the case of <strong>Rexroth</strong> motors of the 2AD, ADF lines and in<br />

the case of linear and rotary kit motors, by loading the<br />

motor parameters with the commissioning software (e.g.<br />

IndraWorks).<br />

• In the case of other asynchronous motors: manual input<br />

according to manufacturer's specification.<br />

• In the case of synchronous motors, the parameter is not<br />

used and automatically set to Aeff = 0.<br />

See also Functional Description "Motor, Mechanical Axis System,<br />

Measuring Systems"<br />

P-0-4005, Flux-generating current, limit value<br />

Input min/max: Default value: Unit:<br />

MPB: var. / 0,000 0,000 A eff<br />

In this parameter a negative limit value for the flux-generating current can<br />

be entered.<br />

This limit value is available for field weakening operation of synchronous<br />

motors and therefore exclusively takes effect for synchronous motors for<br />

which field weakening operation was allowed (see parameter P-0-0045,<br />

Control word of current controller).<br />

Note:<br />

Writing the correct value to this parameter:<br />

• In the case of <strong>Rexroth</strong> motors of the MHD, MKD, MKE and<br />

MSK lines, automatically at initial commissioning.<br />

• In the case of linear and rotary synchronous kit motors by<br />

loading the motor parameters with the commissioning<br />

software (e.g. IndraWorks).<br />

• In the case of other synchronous motors: manual input<br />

according to manufacturer's specification.<br />

• In the case of asynchronous motors, this parameter is<br />

automatically set to Aeff = 0.<br />

See also Functional Description "Limitations"