7-12 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

7.2 Parameterization<br />

Control Panels<br />

Possibilities of Display of<br />

Standard Control Panel<br />

Possible Settings with Standard<br />

Control Panel<br />

Command Activation with<br />

Standard Control Panel<br />

Standard Control Panel<br />

Can be used with control sections CSB01, CSH01, CDB01.<br />

Fig. 7-2: Standard control panel<br />

The standard control panel allows the following displays:<br />

• status of the master communication<br />

• operating status<br />

• activated commands and command diagnoses<br />

• warnings and error diagnoses<br />

• extended displays such as contents of error memories, diagnostic<br />

message memory, operating hours counter of control section,<br />

operating hours counter of power section, type designation of firmware<br />

active in the device, safety technology code (if safety technology option<br />

available)<br />

The following settings can be made with the standard control panel:<br />

• set the drive address (drive number in the bus system of the master<br />

communication)<br />

• set the length of the fiber optic cable<br />

• activate the master communication mode "Easy Startup"<br />

The following commands can be activated with the standard control<br />

panel:<br />

• activate S-0-0262, C07_x Load defaults procedure command (load<br />

controller parameters or basic parameters)<br />

• activate other commands, such as:<br />

• C2200 Backup working memory procedure command<br />

• C2300 Load working memory procedure command<br />

• C2500 Copy IDN from optional memory to internal memory<br />

• C2600 Copy IDN from internal memory to optional memory<br />